Advent Commercial Hardwire/Wireless System
Advent Commercial is integrated security and building control with a difference. It tackles the most demanding commercial applications with more power and capacity than any other system. Compatible with ITI wireless sensors and/or standard hardwire sensors, Advent Commercial has a solution for every installation need.
| Part Number | Part no: 60-562-04 (132 Zone) Part no: 60-562-01 (250 Zone) |
| Color | White |
| Installation | Hybrid - Wireless/Hardwire |
| Sensor Zones | Up to 250 |
| Dimensions | 21.5" wide, 14.75" high, 5.0" deep |
| Mounting | Wall Mounting |
| Compatibility | Security Pro wireless crystal sensors for intrusion, fire, home automation, and environmental monitoring. |
Advent Commercial Fire
Advent Fire delivers advanced hardwire/wireless fire protection for both new and existing commercial fire alarm installations. Advent Fire is easy to install and simple to use.
Advent Fire is suited for large applications or where future expansion may be required.
Part no: 60-562-03 (250 Zones, 8 Partitions)
Part no: 60-562-06 (132 Zones, 4 Partitions)
Advent Fire delivers advanced hardwire/wireless fire protection for both new and existing commercial fire alarm installations. Advent Fire is easy to install and simple to use.
The system is available in two models:
- 60-562-03 has 250 zones, 8 partitions, and up to 250 users
- 60-562-06 has 132 zones, 4 partitions, and up to 100 users
Advent Fire is suited for large applications or where future expansion may be required.
Standard Features
- Six general purpose inputs/outputs, one 12 VDC 2-wire smoke loop, one general purpose input only zone
- Supports up to 132 or 250 supervised, fire-rated hardwire zones (depending on model)
- Supports a maximum of 132 wireless zones (both models)
- 78 pre-defined zone configuration types
- 4 or 8 partitions (based on model)-two account numbers per partition; 32 shared schedules per partition
- 100 or 250 user-programmable access codes (based on model); 4.6 digit lengths allowed
- 800 word vocabulary for voice and display
- 12 VDC, 5 amp auxiliary power output
- On- and off-site telephone access with digitized-voice feedback
- Dual SuperBus Ports-support up to 62 bus devices (31 per port)
- 2,048 event buffer with time and date stamp
- Contact ID™ reporting format
- Up to 16 alphanumeric pagers or cellular phones with paging capability
- Long Range Radio (LORRA); pre-programmed, on-board header
- Network buddy system
- Programming can be downloaded using ITI Advent Downloader
- Flash memory, downloadable upgrades
Specifications
Power Supply:
| Required Transformer | Class I Single Internal 24 VAC, 100 VA |
| Backup Battery | 12 VDC, 17.2 - 18.0 Ah rechargeable, sealed, lead-acid (up to 3—additional enclosure required for third battery) |
| Battery Backup Time | Minimum 24 hours (based on load and number of backup batteries installed) |
| Battery Test | Every 4 hours (default) or 24 hours |
| Fuse | 12 VDC, 5-amp built-in current limiting circuitry: SuperBus outputs limited to 650 mA each, long-range radio output limited to 250 mA |
Telephone/Modem:
| Dialing | DTMF or pulse |
| Modem | Up to 14,400 bps, Bell 103, Bell 212A, V.32bis, V.32, V.22bis, V.22, V.23, V.21, V.42bis |
| Telephone Interface | Line seizure relay, DTMF phone control, line supervision |
| Color: | Fire Red |
| Dimensions: | 21.5" wide, 14.75" high, 5.0" deep |
Approvals
- FCC Parts 15 and 68
- UL 365: Police Station Connected Burglar Alarm Units and Systems
- UL 609: Local Burglar Alarm Units and System
- UL 864: Control Units for Fire Protective Signaling Systems
- Local Non-Coded Fire Alarm Systems
- Auxiliary Fire Alarm Systems
- Central Station Fire Alarm Systems—DACT
- Remote Station Fire Alarm Systems—DACT
- Protected Premise Fire Alarm Systems—DACT
- Type of Service: Automatic Fire Alarm, Manual Fire Alarm, Waterflow Alarm
- UL 985: Household Fire Warning System Units
- UL 1023: Household Burglar Alarm System Units
- UL 1610: Central-Station Burglar Alarm System Units
- UL 1635: Digital Alarm Communicator Systems
- UL 1637: Home Health Care Signaling Equipment
- CSFM California State Fire Marshall
- Complies with NFPA 72 Fire Alarm Code
GE Security Pro 400 NetworX
The NX-4 brings sophisticated security with an economical appeal to the NetworX family of control/communicators. Capable of supporting virtually any of the powerful expander modules from the NetworX family, the NX-4 expands the universe of options available to the smaller system user.
Features:
- 4 fully programmed zones
- Zone doubling options
- Hardwire/wireless hybrid
- All zones programmable as fire and burglary
- 20 customizable pre-configured zone types
- 8 user codes
- 1 duress code
- Up/downloadable with competitor lockout
- Modular design with slide-in PC boards
- Swinger shutdown
- Siren supervision
- Automatic arming with auto retry
- Fire alarm verification
Communication:
- SIA and Contact ID formats
- Supports all major formats
- Event activated pager format
- Flexible auto-test reports
- Failure to communicate reporting
- Reports entering/exiting program mode
- Will communicate alarm events during programming
| Part Number | NX-4 |
| Installation | Hardwire or wireless |
| Sensor Zones | Expandable to 8 hardwire and/or wireless zones |
| Dimensions | 9.25" Wide x 8.25" High x 3.5" Deep |
| Mounting | Wall Mount |
| Compatibility | The complete line of GE Security Pro wireless sensors for intrusion, fire and environmental monitoring. |
GE Security Pro 600 NetworX
With available add-on modules to accommodate enhancements such as wireless integration, X-10 home automation, two-way voice, and cellemetry backup, the NX-6 provides flexible expansion capabilities for mid-size installations.
Features:
- 6 fully programmable zones
- Zone doubling to 12 zones option
- Wireless expansion up to 16 zones
- All zones programmable as fire or burglary
- 2 true partitions
- Up/downloadable with competitor lockout
- Modular design with slide-in PC boards
- 4 on-board outputs (47 events programmable by partition)
- Maximum 8 keypads per partition
- 2-wire or 4-wire smoke detectors
- Automatic arming with auto retry
- Assign zones to one or multiple partitions
- 40 user codes (4 or 6 digit)
- Built-in siren driver/voltage out
- Siren supervision
Communication:
- SIA and Contact ID formats
- Supports all major formats
- Event activated pager format
- Flexible auto-test reports
- Failure to communicate reporting
- Reports entering/exiting program mode
- Will communicate alarm events during programming
| Part Number | NX-6 |
| Installation | Hardwire or wireless |
| Sensor Zones | Expandable to 12 hardwire/16 wireless zones |
| Dimensions | 11.25" Wide x 11.25" High x 3.5" Deep |
| Mounting | Wall Mount |
| Compatibility | The complete line of GE Security Pro wireless sensors for intrusion, fire and environmental monitoring. |
GE Security Pro 800 NetworX
Only from Caddx, the "installer-friendly" X-Pand-A-Can design allows for the first time complete integration of multiple systems modules within one enclosure.
Features:
- Expandable to 48 fully programmable zones
- All zones programmable as fire or burglary
- Maximum 24 keypads
- Wireless expansion up to 48 zones
- Up/downloadable with competitor lockout
- Modular design with slide in PC boards
- 4 on-board outputs (47 events programmable by partition)
- Maximum 8 keypads per partition
- 2-wire or 4-wire smoke detectors
- Assign zones to one or multiple partitions
- 99 four digit or 66 six digit user codes
- Built-in siren driver/voltage out
Partitions:
- Up to 8 true partitions
- Separate account code for each partition
- User code assignment to multiple partitions
- Separate feature selections for each partition
- Independent entry/exit delays for each partition
185 Event Log:
- Includes date, time, event and partition number
Communication:
- SIA and contact ID formats
- Supports all major formats
- Event activated pager format
- Flexible auto-test reports
- Failure to communicate reporting
- Reports entering/exiting program mode
- Will communicate alarm events during programming
Hardwire Zone Expansion:
- The NX-8 is expandable to 16 zones by zone doubling, or 48 zones with expander modules
- NX-216 -16 zone expansion module
- Can mount up to 2,500 feet from control
- Box tamper input
- Separate auxiliary power supervision
| Part Number | NX-8 |
| Installation | Hardwire or wireless |
| Sensor Zones | Expandable to 48 hardwire and/or wireless zones |
| Dimensions | 11.25" Wide x 11.25" High x 3.5" Deep |
| Mounting | Wall Mount |
| Compatibility | The complete line of GE Security Pro wireless sensors for intrusion, fire and environmental monitoring. |
GE Security Pro 801 NetworX System
The most versatile NetworX control available, the NX-8E offers from 8 to 192 zones. Ideal for home automation up to medium-sized commercial installations, the NX-8E is flexible enough to meet the most demanding applications.
UL 609*, UL635, UL 985, UL 1023, UL 1610, UL 1635, UL 1637
*The UL 609 rating only applies when using the NX-003C UL commercial enclosure.
Features:
- Expandable to 192 fully programmable zones
- All zones programmable as fire or burglary
- Maximum 24 keypads
- Wireless expansion up to 192 zones
- Up/downloadable with competitor lockout
- Up to 8 partitions
- Maximum 8 keypads per partition
- 2-wire or 4-wire smoke detectors
- Automatic arming with auto retry
- Assign zones to one or multiple partitions
- 240 four digit user codes
- Zone activity monitor
- Late-to-close/early-to-open reporting
- Built-in RS-232 serial interface for printer or direct computer connect (adapter cable needed)
- 2 on-board relays (one Form A,one Form B)
- 2 separately ptc protected auxiliary power outputs
- 2 amp power supply
Partitions:
- Up to 8 true partitions
- Separate account code for each partition
- User code assignment to multiple partitions
- Separate feature selections for each partition
- Independent entry/exit delays for each partition
- 512 Event Log
- Includes date,time,event and partition number
Communication:
- SIA and contact ID formats
- Supports all major formats
- Event activated pager format
- Flexible auto-test reports
- Failure to communicate reporting
- Reports entering/exiting program mode
- Will communicate alarm events during programming
| Part Number | NX-8E |
| Installation | Hardwire or wireless |
| Sensor Zones | Expandable to 192 hardwire and/or wireless zones |
| Dimensions | 11.25" Wide x 11.25" High x x3.5" Deep |
| Mounting | Wall Mount |
| Compatibility | The complete line of GE Security Pro wireless sensors for intrusion, fire and environmental monitoring. |